{"id":2637,"date":"2025-10-29T19:13:09","date_gmt":"2025-10-29T19:13:09","guid":{"rendered":"https:\/\/new-ageco.com\/?post_type=product&#038;p=2637"},"modified":"2025-11-02T19:47:42","modified_gmt":"2025-11-02T19:47:42","slug":"strut-channels","status":"publish","type":"product","link":"https:\/\/new-ageco.com\/ar\/product\/strut-channels\/","title":{"rendered":"Strut Channels"},"content":{"rendered":"<h3><b>Product Designation System<\/b><\/h3>\n<p><b>NAC-SCHN-XX-X.X | NAC = New Age Corporation | SCHN = Strut Channel | XX = Profile dimensions (height \u00d7 width in mm) | X.X = Material thickness (mm)<\/b><\/p>\n<h2><b>Complete Technical Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Material<\/b><\/td>\n<td><span style=\"font-weight: 400\">Mild Steel (ES 138 \/ A36)<\/span><\/td>\n<td><b>Construction<\/b><\/td>\n<td><span style=\"font-weight: 400\">Cold-formed slotted channel<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Channel Profiles<\/b><\/td>\n<td><span style=\"font-weight: 400\">Single, Double (back-to-back), Deep, Shallow<\/span><\/td>\n<td><b>Standard Lengths<\/b><\/td>\n<td><span style=\"font-weight: 400\">3m, 6m (custom available)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Thickness Range<\/b><\/td>\n<td><span style=\"font-weight: 400\">1.5mm, 2.0mm, 2.5mm, 3.0mm<\/span><\/td>\n<td><b>Slot Patterns<\/b><\/td>\n<td><span style=\"font-weight: 400\">12\u00d730mm, 14\u00d728mm (custom available)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Finish Options<\/b><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galv \/ Hot-Dip \/ Pre-Galv \/ Plain<\/span><\/td>\n<td><b>Operating Temp<\/b><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +150\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>System Compatibility<\/b><\/td>\n<td><span style=\"font-weight: 400\">M8, M10, M12 hardware &amp; fittings<\/span><\/td>\n<td><b>Load Capacity<\/b><\/td>\n<td><span style=\"font-weight: 400\">Profile and span dependent<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Modulus of Elasticity<\/b><\/td>\n<td><span style=\"font-weight: 400\">21 kN\/cm\u00b2 (210 GPa)<\/span><\/td>\n<td><b>Standards<\/b><\/td>\n<td><span style=\"font-weight: 400\">Egyptian Code \/ ASTM A653<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Standard Product Range &amp; Structural Properties<\/b><\/h2>\n<h3><b>Profile Specifications<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Product Code<\/b><\/td>\n<td><b>Profile Size (H\u00d7W\u00d7T)<\/b><\/td>\n<td><b>Area of Section (cm\u00b2)<\/b><\/td>\n<td><b>Moment of Inertia Ixx (cm\u2074)<\/b><\/td>\n<td><b>Moment of Inertia Iyy (cm\u2074)<\/b><\/td>\n<td><b>Weight (kg\/m)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-1.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d721\u00d71.5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.42<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.7<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.34<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.3<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-1.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d741\u00d71.5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.02<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.87<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.68<\/span><\/td>\n<td><span style=\"font-weight: 400\">8.0<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-2.0<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d721\u00d72.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.55<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.88<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.25<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.3<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-2.0<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d741\u00d72.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.34<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.59<\/span><\/td>\n<td><span style=\"font-weight: 400\">6.99<\/span><\/td>\n<td><span style=\"font-weight: 400\">10.5<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-2.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d721\u00d72.5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.67<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.03<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.07<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.3<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-2.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">41\u00d741\u00d72.5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.67<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.87<\/span><\/td>\n<td><span style=\"font-weight: 400\">8.76<\/span><\/td>\n<td><span style=\"font-weight: 400\">13.1<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>Structural Load Properties<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Product Code<\/b><\/td>\n<td><b>Section Modulus Zxx (cm\u00b3)<\/b><\/td>\n<td><b>Section Modulus Zyy (cm\u00b3)<\/b><\/td>\n<td><b>Warping Constant (cm\u2076)<\/b><\/td>\n<td><b>Torsional Constant (cm\u2074)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-1.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">0.6<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.7<\/span><\/td>\n<td><span style=\"font-weight: 400\">17.49<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.01<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-1.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">1.76<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.87<\/span><\/td>\n<td><span style=\"font-weight: 400\">114.17<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.02<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-2.0<\/b><\/td>\n<td><span style=\"font-weight: 400\">0.75<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.88<\/span><\/td>\n<td><span style=\"font-weight: 400\">21.34<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.02<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-2.0<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.18<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.59<\/span><\/td>\n<td><span style=\"font-weight: 400\">138.49<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.03<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-21-2.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">0.89<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.03<\/span><\/td>\n<td><span style=\"font-weight: 400\">24.34<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.06<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SCHN-41-2.5<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.72<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.87<\/span><\/td>\n<td><span style=\"font-weight: 400\">171.52<\/span><\/td>\n<td><span style=\"font-weight: 400\">0.07<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>Allowable Stress Values (All Profiles)<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Allowable Bending Stress:<\/b><span style=\"font-weight: 400\"> 21.82 kN\/cm\u00b2 (218.2 MPa)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Allowable Shear Stress:<\/b><span style=\"font-weight: 400\"> 12.6 kN\/cm\u00b2 (126 MPa)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Modulus of Elasticity:<\/b><span style=\"font-weight: 400\"> 21 kN\/cm\u00b2 (210 GPa)<\/span><\/li>\n<\/ul>\n<p><i><span style=\"font-weight: 400\">Note: These values are based on mild steel ES 138 (ASTM A36 equivalent) with a 3:1 safety factor. Actual allowable loads depend on span length, loading configuration, and support conditions. Consult load tables for specific applications.<\/span><\/i><\/p>\n<h2><b>Slot Specifications &amp; Hardware Compatibility<\/b><\/h2>\n<h3><b>Standard Slot Patterns<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Slot Type<\/b><\/td>\n<td><b>Dimensions (W\u00d7L)<\/b><\/td>\n<td><b>Spacing<\/b><\/td>\n<td><b>Compatible Hardware<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Standard 12\/30<\/b><\/td>\n<td><span style=\"font-weight: 400\">12mm \u00d7 30mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">50mm centers<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8, M10 bolts<\/span><\/td>\n<td><span style=\"font-weight: 400\">General MEP support<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Standard 14\/28<\/b><\/td>\n<td><span style=\"font-weight: 400\">14mm \u00d7 28mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">50mm centers<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10, M12 bolts<\/span><\/td>\n<td><span style=\"font-weight: 400\">Heavy-duty applications<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Custom Pattern<\/b><\/td>\n<td><span style=\"font-weight: 400\">Project-specific<\/span><\/td>\n<td><span style=\"font-weight: 400\">Variable<\/span><\/td>\n<td><span style=\"font-weight: 400\">Any threaded hardware<\/span><\/td>\n<td><span style=\"font-weight: 400\">Special projects<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>Hardware System Components<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The New Age Strut Channel System is compatible with a complete range of connecting hardware:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>Channel Nuts:<\/b><span style=\"font-weight: 400\"> Spring nuts, standard nuts (M8, M10, M12)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Brackets &amp; Fittings:<\/b><span style=\"font-weight: 400\"> 90\u00b0 angles, flat plates, beam clamps, floor flanges<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Threaded Rods:<\/b><span style=\"font-weight: 400\"> M8, M10, M12, M16 (various lengths)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Pipe Clamps:<\/b><span style=\"font-weight: 400\"> Adjustable pipe clamps fitting into channel slots<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Beam Clamps:<\/b><span style=\"font-weight: 400\"> For attachment to structural steel<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Post Bases:<\/b><span style=\"font-weight: 400\"> For floor-mounted installations<\/span><\/li>\n<\/ul>\n<h2><b>Material &amp; Finish Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Finish Type<\/b><\/td>\n<td><b>Coating Specification<\/b><\/td>\n<td><b>Recommended Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Electro-Galvanized (EG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">12\u201325 \u03bcm per ASTM B633<\/span><\/td>\n<td><span style=\"font-weight: 400\">Indoor mechanical\/electrical rooms, dry environments<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Hot-Dip Galvanized (HDG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u226555 \u03bcm per ASTM A153<\/span><\/td>\n<td><span style=\"font-weight: 400\">Outdoor installations, industrial plants, coastal zones, high-humidity areas<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Pre-Galvanized (PG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standard mill coating per ASTM A653<\/span><\/td>\n<td><span style=\"font-weight: 400\">General construction, moderate indoor conditions<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Plain (Uncoated)<\/b><\/td>\n<td><span style=\"font-weight: 400\">No coating<\/span><\/td>\n<td><span style=\"font-weight: 400\">Paint-ready installations or controlled environments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Application Selection Guide<\/b><\/h2>\n<h3><b>Mechanical Applications<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Application<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<td><b>Recommended Profile<\/b><\/td>\n<td><b>Finish<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Pipe Racks<\/b><\/td>\n<td><span style=\"font-weight: 400\">Multi-line distribution supports<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0\/2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Tunnel Pipe Stanchions<\/b><\/td>\n<td><span style=\"font-weight: 400\">Underground utility corridors<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Equipment Frames<\/b><\/td>\n<td><span style=\"font-weight: 400\">Pump skids, mechanical supports<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0\/2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Pipe Height Adjustment<\/b><\/td>\n<td><span style=\"font-weight: 400\">Elevated distribution systems<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-2.0\/41-2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Roof Pipe Supports<\/b><\/td>\n<td><span style=\"font-weight: 400\">Rooftop HVAC piping<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>Electrical Applications<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Application<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<td><b>Recommended Profile<\/b><\/td>\n<td><b>Finish<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Conduit Supports<\/b><\/td>\n<td><span style=\"font-weight: 400\">EMT\/rigid conduit mounting<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-1.5\/2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Cable Tray Systems<\/b><\/td>\n<td><span style=\"font-weight: 400\">Ladder tray support structures<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0\/2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Raceway Systems<\/b><\/td>\n<td><span style=\"font-weight: 400\">Wireway and trough mounting<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Lighting Fixture Supports<\/b><\/td>\n<td><span style=\"font-weight: 400\">Suspended lighting frameworks<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-1.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Beam Adjustments<\/b><\/td>\n<td><span style=\"font-weight: 400\">Structural attachment points<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>Industrial Applications<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Application<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<td><b>Recommended Profile<\/b><\/td>\n<td><b>Finish<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Racks and Shelving<\/b><\/td>\n<td><span style=\"font-weight: 400\">Storage and material handling<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0\/2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Plain or HDG<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Trolley Systems<\/b><\/td>\n<td><span style=\"font-weight: 400\">Overhead material transport<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Production Line Supports<\/b><\/td>\n<td><span style=\"font-weight: 400\">Manufacturing equipment frames<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0\/2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Plain (painted)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Machine Frames<\/b><\/td>\n<td><span style=\"font-weight: 400\">Equipment mounting platforms<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Plain or HDG<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Partition &amp; Wall Framing<\/b><\/td>\n<td><span style=\"font-weight: 400\">Interior dividers and enclosures<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-1.5\/2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Pre-Galvanized<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Load Capacity Guidelines<\/b><\/h2>\n<h3><b>Simple Span Load Tables (Uniformly Distributed Load)<\/b><\/h3>\n<p><b>Safety Factor: 3:1 | Based on Allowable Bending Stress of 21.82 kN\/cm\u00b2<\/b><\/p>\n<h4><b>NAC-SCHN-41-2.0 (41\u00d741\u00d72.0mm) &#8211; Most Common Profile<\/b><\/h4>\n<table>\n<tbody>\n<tr>\n<td><b>Span (m)<\/b><\/td>\n<td><b>Max UDL (kg\/m)<\/b><\/td>\n<td><b>Total Load (kg)<\/b><\/td>\n<td><b>Deflection Limit<\/b><\/td>\n<td><b>Typical Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">950<\/span><\/td>\n<td><span style=\"font-weight: 400\">950<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Heavy pipe clusters<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">420<\/span><\/td>\n<td><span style=\"font-weight: 400\">630<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Multi-pipe racks<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">2.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">235<\/span><\/td>\n<td><span style=\"font-weight: 400\">470<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Standard pipe supports<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">2.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">150<\/span><\/td>\n<td><span style=\"font-weight: 400\">375<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Light distribution<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">3.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">105<\/span><\/td>\n<td><span style=\"font-weight: 400\">315<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Conduit\/cable tray<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><b>NAC-SCHN-41-2.5 (41\u00d741\u00d72.5mm) &#8211; Heavy Duty Profile<\/b><\/h4>\n<table>\n<tbody>\n<tr>\n<td><b>Span (m)<\/b><\/td>\n<td><b>Max UDL (kg\/m)<\/b><\/td>\n<td><b>Total Load (kg)<\/b><\/td>\n<td><b>Deflection Limit<\/b><\/td>\n<td><b>Typical Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">1,210<\/span><\/td>\n<td><span style=\"font-weight: 400\">1,210<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Heavy equipment frames<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">535<\/span><\/td>\n<td><span style=\"font-weight: 400\">803<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Large pipe racks<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">2.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">300<\/span><\/td>\n<td><span style=\"font-weight: 400\">600<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Fire protection mains<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">2.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">192<\/span><\/td>\n<td><span style=\"font-weight: 400\">480<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">HVAC distribution<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">3.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">134<\/span><\/td>\n<td><span style=\"font-weight: 400\">402<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Multi-line supports<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><b>NAC-SCHN-21-2.0 (41\u00d721\u00d72.0mm) &#8211; Light Duty Profile<\/b><\/h4>\n<table>\n<tbody>\n<tr>\n<td><b>Span (m)<\/b><\/td>\n<td><b>Max UDL (kg\/m)<\/b><\/td>\n<td><b>Total Load (kg)<\/b><\/td>\n<td><b>Deflection Limit<\/b><\/td>\n<td><b>Typical Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">180<\/span><\/td>\n<td><span style=\"font-weight: 400\">180<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Light conduit<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">1.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">80<\/span><\/td>\n<td><span style=\"font-weight: 400\">120<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Cable support<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">2.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">45<\/span><\/td>\n<td><span style=\"font-weight: 400\">90<\/span><\/td>\n<td><span style=\"font-weight: 400\">L\/240<\/span><\/td>\n<td><span style=\"font-weight: 400\">Lighting fixtures<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><i><span style=\"font-weight: 400\">Note: These are simplified load tables for preliminary sizing. For critical applications, final spans and loads must be verified by structural calculation considering actual loading conditions, support restraints, and local code requirements.<\/span><\/i><\/p>\n<h2><b>Installation Requirements<\/b><\/h2>\n<h3><b>Pre-Installation Planning<\/b><\/h3>\n<p><b>Structural Coordination:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Verify structural capacity of mounting surfaces (concrete slabs, beams, walls)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Confirm anchor spacing and type per structural engineer&#8217;s approval<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Review MEP coordination drawings for clearances and load paths<\/span><\/li>\n<\/ul>\n<p><b>Load Calculation:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Calculate total weight: (pipe\/conduit + fluid + insulation + channel self-weight)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Determine maximum span based on load tables above<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Select profile thickness based on calculated bending moment and shear<\/span><\/li>\n<\/ul>\n<p><b>Hardware Selection:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Choose appropriate channel nuts and bolts (M8 for light loads, M10\/M12 for heavy)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Select beam clamps or anchors rated for calculated loads<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Verify threaded rod diameter matches load requirements<\/span><\/li>\n<\/ul>\n<h3><b>Installation Procedure<\/b><\/h3>\n<ol>\n<li><b> Install primary support points<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Mark anchor locations per approved shop drawings<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Install concrete anchors, beam clamps, or structural attachments<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify anchor torque per manufacturer specifications<\/span><\/p>\n<ol start=\"2\">\n<li><b> Position and level strut channel<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Cut channel to required length using metal saw or band saw<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Deburr cut edges to prevent injury and ensure proper fit<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Position channel and verify level using spirit level or laser<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Secure channel to anchors with appropriate hardware<\/span><\/p>\n<ol start=\"3\">\n<li><b> Install cross-bracing (if required)<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Add perpendicular or diagonal channels for lateral stability<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Use corner brackets or flat plates to connect channels<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Ensure all connections are tight and properly torqued<\/span><\/p>\n<ol start=\"4\">\n<li><b> Mount MEP components<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Install pipe clamps, cable tray brackets, or conduit supports into channel slots<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Position components at designed spacing<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Tighten all fasteners to recommended torque:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M8: 12\u201315 Nm<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M10: 25\u201330 Nm<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M12: 45\u201350 Nm<\/span><\/li>\n<\/ul>\n<ol start=\"5\">\n<li><b> Verify final alignment and loading<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Check level and alignment across entire support run<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify no interference with other trades<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Inspect all connections for proper engagement<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Perform visual deflection check under load<\/span><\/p>\n<h2><b>System Design Considerations<\/b><\/h2>\n<h3><b>Span Optimization<\/b><\/h3>\n<p><b>To minimize deflection and maximize efficiency:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Keep spans as short as practical<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Add intermediate supports for heavily loaded channels<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Use deeper profiles (41\u00d741) for longer spans<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Consider back-to-back double channels for extreme loads<\/span><\/li>\n<\/ul>\n<h3><b>Connection Design<\/b><\/h3>\n<p><b>For reliable structural performance:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Minimum bolt engagement: 3 full threads<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Minimum edge distance: 1.5\u00d7 hole diameter<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Use lock washers or lock nuts to prevent loosening<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Avoid over-tightening which can deform thin channels<\/span><\/li>\n<\/ul>\n<h3><b>Seismic Considerations<\/b><\/h3>\n<p><b>In seismic zones, additional requirements apply:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Lateral bracing at maximum 12m spacing (or per code)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Diagonal bracing in both horizontal directions<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Positive connection to structure (no friction-only supports)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Engineer-stamped calculations for seismic loads<\/span><\/li>\n<\/ul>\n<h2><b>Why Specify New Age Strut Channels?<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Advantage<\/b><\/td>\n<td><b>Benefit to Your Project<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Consistent Steel Thickness<\/b><\/td>\n<td><span style=\"font-weight: 400\">Predictable structural performance across batches \u2013 eliminates field surprises<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Automated Slotted Cutting<\/b><\/td>\n<td><span style=\"font-weight: 400\">Clean, precise slot edges \u2013 fast hardware alignment, no filed edges or burrs<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Certified Galvanization<\/b><\/td>\n<td><span style=\"font-weight: 400\">Extended service life in industrial and outdoor environments \u2013 25+ year durability<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Modular System Design<\/b><\/td>\n<td><span style=\"font-weight: 400\">Zero on-site welding \u2013 rapid installation, easy field modifications<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Universal Hardware Compatibility<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standard slot patterns work with all major brands \u2013 no proprietary lock-in<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>100% Egyptian Manufacturing<\/b><\/td>\n<td><span style=\"font-weight: 400\">3\u20137 day delivery (Cairo\/Giza), competitive pricing, stable supply chain<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Load Tables &amp; Engineering Support<\/b><\/td>\n<td><span style=\"font-weight: 400\">Structural calculations provided \u2013 reduces engineering time and liability<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Profile Selection Guide<\/b><\/h2>\n<h3><b>Choosing the Right Channel Profile<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>If Your Application Requires&#8230;<\/b><\/td>\n<td><b>Then Select&#8230;<\/b><\/td>\n<td><b>Reason<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Long spans (&gt;2.5m) with moderate loads<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Higher section modulus reduces deflection<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Heavy concentrated loads<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.5 or double channel<\/span><\/td>\n<td><span style=\"font-weight: 400\">Maximum moment capacity<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Light electrical conduit support<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-1.5<\/span><\/td>\n<td><span style=\"font-weight: 400\">Cost-effective, adequate strength<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Standard pipe racks (1.5\u20132.5m span)<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-41-2.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">Best balance of strength and economy<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Outdoor or corrosive environments<\/span><\/td>\n<td><span style=\"font-weight: 400\">Any profile with HDG finish<\/span><\/td>\n<td><span style=\"font-weight: 400\">Superior corrosion resistance<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Tight budget, indoor dry environment<\/span><\/td>\n<td><span style=\"font-weight: 400\">NAC-SCHN-21-2.0 with PG finish<\/span><\/td>\n<td><span style=\"font-weight: 400\">Minimum cost while meeting requirements<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Standards &amp; Certifications<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>Egyptian Mechanical &amp; Electrical Codes<\/b><span style=\"font-weight: 400\"> \u2013 MEP support system requirements<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>MSS SP-58<\/b><span style=\"font-weight: 400\"> \u2013 Pipe support classification reference<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM A653<\/b><span style=\"font-weight: 400\"> \u2013 Steel sheet, zinc-coated (galvanized) specification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM A36<\/b><span style=\"font-weight: 400\"> \u2013 Structural steel equivalent (ES 138)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM A123<\/b><span style=\"font-weight: 400\"> \u2013 Hot-dip galvanized coating specification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM B633<\/b><span style=\"font-weight: 400\"> \u2013 Electro-galvanized coating specification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ISO 9001:2015<\/b><span style=\"font-weight: 400\"> \u2013 Quality management system certification<\/span><\/li>\n<\/ul>\n<h2><b>Engineering Support<\/b><\/h2>\n<p><b>Technical Assistance:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Span and load calculation verification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Profile selection for specific applications<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Connection design and hardware specification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Submittal preparation for consultant approval<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Shop drawing coordination and review<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Seismic bracing design (coordination with structural engineer)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">On-site installation guidance and problem-solving<\/span><\/li>\n<\/ul>\n<p><b>Response Time:<\/b><span style=\"font-weight: 400\"> Technical queries answered within 24 hours<\/span><\/p>\n<p><b>After-Sales Support:<\/b><span style=\"font-weight: 400\"> Product issue resolution, installation assistance, fast replacement for defects<\/span><\/p>\n<p><b>Custom Solutions:<\/b><span style=\"font-weight: 400\"> Special profiles, slot patterns, lengths, and finishes available for large projects or unique requirements<\/span><\/p>\n<h2><b>System Limitations &amp; Best Practices<\/b><\/h2>\n<h3><b>When NOT to Use Strut Channels<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u274c <\/span><b>Primary structural members<\/b><span style=\"font-weight: 400\"> (columns, beams supporting building weight)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>High-vibration applications without dampening<\/b><span style=\"font-weight: 400\"> (near unbalanced rotating equipment)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Corrosive chemical exposure<\/b><span style=\"font-weight: 400\"> (acids, alkalis without proper coating)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Impact loads or dynamic loading<\/b><span style=\"font-weight: 400\"> (forklift traffic, crane runways)<\/span><\/p>\n<h3><b>Best Practices for Long Service Life<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u2713 Use Hot-Dip Galvanized finish for all outdoor or high-humidity applications<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Inspect and re-torque connections after 30 days of initial installation<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Avoid field cutting of galvanized channels when possible (touch up cut edges if required)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Use spring nuts for applications subject to thermal cycling<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Maintain minimum 50mm clearance from concrete for drainage<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Follow load tables conservatively \u2013 do not exceed recommended spans<\/span><\/p>\n<h2><b>Trusted on Major Projects<\/b><\/h2>\n<p><span style=\"font-weight: 400\">New Age Strut Channels are specified across Egypt&#8217;s most demanding MEP and industrial installations:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Administrative Capital \u2013 Government building MEP support infrastructure<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Opera House Complex \u2013 Electrical and mechanical distribution systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Military Complex Projects \u2013 Secure facility utility support frameworks<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Giza Development \u2013 High-rise tower MEP installations<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Industrial Manufacturing Plants \u2013 Production line equipment framing<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Petroleum Refineries \u2013 Process piping support racks<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Wastewater Treatment Facilities \u2013 Heavy pipe rack systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Data Centers \u2013 Raised floor cable tray and conduit support<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Metro Stations \u2013 Tunnel utility distribution frameworks<\/span><\/li>\n<\/ul>\n<p><i><span style=\"font-weight: 400\">Trusted by leading contractors: Orascom Construction, Hassan Allam Holding, Arab Contractors<\/span><\/i><\/p>\n<h1><b>NEW AGE<\/b><\/h1>\n<p><i><span style=\"font-weight: 400\">\u062f\u0639\u0645 \u0645\u0627 \u064a\u0628\u0646\u064a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644<\/span><\/i><\/p>\n<p><span style=\"font-weight: 400\">100% Egyptian Manufacturing | ISO 9001:2015 Certified | Trusted by Egypt&#8217;s Top Contractors<\/span><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<h2><b>STRUT CHANNELS | NAC-SCHN Series<\/b><\/h2>\n<h3><b>Modular Structural Support Framework for MEP &amp; &#8230; <\/p>","protected":false},"featured_media":2707,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[97,96],"product_tag":[],"class_list":{"0":"post-2637","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fire-fighting-solutions","7":"product_cat-hvac-solutions","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product\/2637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/comments?post=2637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media\/2707"}],"wp:attachment":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media?parent=2637"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2637"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2637"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}