{"id":2631,"date":"2025-10-29T19:07:22","date_gmt":"2025-10-29T19:07:22","guid":{"rendered":"https:\/\/new-ageco.com\/?post_type=product&#038;p=2631"},"modified":"2025-10-30T19:38:52","modified_gmt":"2025-10-30T19:38:52","slug":"riser-clamp-with-linning","status":"publish","type":"product","link":"https:\/\/new-ageco.com\/ar\/product\/riser-clamp-with-linning\/","title":{"rendered":"Riser-Clamp With Linning"},"content":{"rendered":"<h3><b>Product Designation System<\/b><\/h3>\n<p><b>NAC-RCL-XX | NAC = New Age Corporation | RCL = Riser Clamp with Lining | XX = Nominal pipe size (DN)<\/b><\/p>\n<h2><b>Complete Technical Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Material (Clamp)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Mild Steel (ES 138 \/ A36)<\/span><\/td>\n<td><b>Construction<\/b><\/td>\n<td><span style=\"font-weight: 400\">Two-piece flat bar, bolted assembly<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Lining Material<\/b><\/td>\n<td><span style=\"font-weight: 400\">EPDM high-density rubber<\/span><\/td>\n<td><b>Pipe Size Range<\/b><\/td>\n<td><span style=\"font-weight: 400\">DN15 to DN600 (\u00bd&#8221; to 24&#8243;)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Finish Options<\/b><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galv \/ Hot-Dip \/ Pre-Galv \/ Plain<\/span><\/td>\n<td><b>Operating Temp<\/b><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +110\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Mounting Method<\/b><\/td>\n<td><span style=\"font-weight: 400\">Rests on structural slab or beam<\/span><\/td>\n<td><b>Noise Reduction<\/b><\/td>\n<td><span style=\"font-weight: 400\">Up to 18 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Load Type<\/b><\/td>\n<td><span style=\"font-weight: 400\">Carries vertical dead load (pipe + fluid)<\/span><\/td>\n<td><b>Bolt Size<\/b><\/td>\n<td><span style=\"font-weight: 400\">M10, M12, M16, M20<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Installation<\/b><\/td>\n<td><span style=\"font-weight: 400\">Bolted around pipe below load point<\/span><\/td>\n<td><b>Standards<\/b><\/td>\n<td><span style=\"font-weight: 400\">Egyptian Code \/ MSS SP-58<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Load Capacity &amp; Support Spacing Guidelines<\/b><\/h2>\n<p><i><span style=\"font-weight: 400\">The following load capacities are based on vertical pipe weight plus fluid content, with a 3:1 safety factor. Riser clamps must rest on structural floors, beams, or steel brackets\u2014NOT suspended from threaded rod.<\/span><\/i><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Product Code<\/b><\/td>\n<td><b>Pipe Size<\/b><\/td>\n<td><b>Pipe OD (mm)<\/b><\/td>\n<td><b>Length Between Hole Centers (mm)<\/b><\/td>\n<td><b>Bolt Size<\/b><\/td>\n<td><b>Max Load (kg)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL15<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00bd&#8221; (DN15)<\/span><\/td>\n<td><span style=\"font-weight: 400\">21.3<\/span><\/td>\n<td><span style=\"font-weight: 400\">57<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL20<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00be&#8221; (DN20)<\/span><\/td>\n<td><span style=\"font-weight: 400\">26.7<\/span><\/td>\n<td><span style=\"font-weight: 400\">68<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL25<\/b><\/td>\n<td><span style=\"font-weight: 400\">1&#8243; (DN25)<\/span><\/td>\n<td><span style=\"font-weight: 400\">33.4<\/span><\/td>\n<td><span style=\"font-weight: 400\">76<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL32<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bc&#8221; (DN32)<\/span><\/td>\n<td><span style=\"font-weight: 400\">42.1<\/span><\/td>\n<td><span style=\"font-weight: 400\">90<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL40<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bd&#8221; (DN40)<\/span><\/td>\n<td><span style=\"font-weight: 400\">48.2<\/span><\/td>\n<td><span style=\"font-weight: 400\">110<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL50<\/b><\/td>\n<td><span style=\"font-weight: 400\">2&#8243; (DN50)<\/span><\/td>\n<td><span style=\"font-weight: 400\">60.3<\/span><\/td>\n<td><span style=\"font-weight: 400\">130<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><b>1,250<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL65<\/b><\/td>\n<td><span style=\"font-weight: 400\">2\u00bd&#8221; (DN65)<\/span><\/td>\n<td><span style=\"font-weight: 400\">73.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">142<\/span><\/td>\n<td><span style=\"font-weight: 400\">M12<\/span><\/td>\n<td><b>1,250<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL80<\/b><\/td>\n<td><span style=\"font-weight: 400\">3&#8243; (DN80)<\/span><\/td>\n<td><span style=\"font-weight: 400\">88.9<\/span><\/td>\n<td><span style=\"font-weight: 400\">161<\/span><\/td>\n<td><span style=\"font-weight: 400\">M12<\/span><\/td>\n<td><b>1,750<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL100<\/b><\/td>\n<td><span style=\"font-weight: 400\">4&#8243; (DN100)<\/span><\/td>\n<td><span style=\"font-weight: 400\">114.3<\/span><\/td>\n<td><span style=\"font-weight: 400\">190<\/span><\/td>\n<td><span style=\"font-weight: 400\">M12<\/span><\/td>\n<td><b>1,850<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL150<\/b><\/td>\n<td><span style=\"font-weight: 400\">6&#8243; (DN150)<\/span><\/td>\n<td><span style=\"font-weight: 400\">168.3<\/span><\/td>\n<td><span style=\"font-weight: 400\">258<\/span><\/td>\n<td><span style=\"font-weight: 400\">M16<\/span><\/td>\n<td><b>2,250<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL200<\/b><\/td>\n<td><span style=\"font-weight: 400\">8&#8243; (DN200)<\/span><\/td>\n<td><span style=\"font-weight: 400\">219.1<\/span><\/td>\n<td><span style=\"font-weight: 400\">333<\/span><\/td>\n<td><span style=\"font-weight: 400\">M16<\/span><\/td>\n<td><b>2,250<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL250<\/b><\/td>\n<td><span style=\"font-weight: 400\">10&#8243; (DN250)<\/span><\/td>\n<td><span style=\"font-weight: 400\">273.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">409<\/span><\/td>\n<td><span style=\"font-weight: 400\">M16<\/span><\/td>\n<td><b>3,600<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL300<\/b><\/td>\n<td><span style=\"font-weight: 400\">12&#8243; (DN300)<\/span><\/td>\n<td><span style=\"font-weight: 400\">323.8<\/span><\/td>\n<td><span style=\"font-weight: 400\">467<\/span><\/td>\n<td><span style=\"font-weight: 400\">M20<\/span><\/td>\n<td><b>3,600<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL400<\/b><\/td>\n<td><span style=\"font-weight: 400\">16&#8243; (DN400)<\/span><\/td>\n<td><span style=\"font-weight: 400\">406.4<\/span><\/td>\n<td><span style=\"font-weight: 400\">583<\/span><\/td>\n<td><span style=\"font-weight: 400\">M20<\/span><\/td>\n<td><b>4,500<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL500<\/b><\/td>\n<td><span style=\"font-weight: 400\">20&#8243; (DN500)<\/span><\/td>\n<td><span style=\"font-weight: 400\">508.0<\/span><\/td>\n<td><span style=\"font-weight: 400\">708<\/span><\/td>\n<td><span style=\"font-weight: 400\">M20<\/span><\/td>\n<td><b>4,500<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL600<\/b><\/td>\n<td><span style=\"font-weight: 400\">24&#8243; (DN600)<\/span><\/td>\n<td><span style=\"font-weight: 400\">609.6<\/span><\/td>\n<td><span style=\"font-weight: 400\">833<\/span><\/td>\n<td><span style=\"font-weight: 400\">M20<\/span><\/td>\n<td><b>5,800<\/b><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><i><span style=\"font-weight: 400\">Note: Maximum load includes pipe self-weight, fluid content, and insulation. Consult structural engineer for floor loading verification on multi-story risers. For seismic zones, additional lateral restraints may be required per local codes.<\/span><\/i><\/p>\n<h2><b>Dimensional Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Code<\/b><\/td>\n<td><b>Pipe Size<\/b><\/td>\n<td><b>Clamp Width (mm)<\/b><\/td>\n<td><b>Material Thickness<\/b><\/td>\n<td><b>EPDM Thickness<\/b><\/td>\n<td><b>Weight (approx)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL15<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00bd&#8221; (DN15)<\/span><\/td>\n<td><span style=\"font-weight: 400\">40<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">3 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">420 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL20<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00be&#8221; (DN20)<\/span><\/td>\n<td><span style=\"font-weight: 400\">45<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">3 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">480 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL25<\/b><\/td>\n<td><span style=\"font-weight: 400\">1&#8243; (DN25)<\/span><\/td>\n<td><span style=\"font-weight: 400\">50<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">3 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">560 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL32<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bc&#8221; (DN32)<\/span><\/td>\n<td><span style=\"font-weight: 400\">55<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">3 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">680 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL40<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bd&#8221; (DN40)<\/span><\/td>\n<td><span style=\"font-weight: 400\">60<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">4 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">780 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL50<\/b><\/td>\n<td><span style=\"font-weight: 400\">2&#8243; (DN50)<\/span><\/td>\n<td><span style=\"font-weight: 400\">70<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">4 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.2 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL65<\/b><\/td>\n<td><span style=\"font-weight: 400\">2\u00bd&#8221; (DN65)<\/span><\/td>\n<td><span style=\"font-weight: 400\">80<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">4 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.5 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL80<\/b><\/td>\n<td><span style=\"font-weight: 400\">3&#8243; (DN80)<\/span><\/td>\n<td><span style=\"font-weight: 400\">90<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">4 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.9 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL100<\/b><\/td>\n<td><span style=\"font-weight: 400\">4&#8243; (DN100)<\/span><\/td>\n<td><span style=\"font-weight: 400\">110<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.8 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL150<\/b><\/td>\n<td><span style=\"font-weight: 400\">6&#8243; (DN150)<\/span><\/td>\n<td><span style=\"font-weight: 400\">140<\/span><\/td>\n<td><span style=\"font-weight: 400\">5.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">4.2 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL200<\/b><\/td>\n<td><span style=\"font-weight: 400\">8&#8243; (DN200)<\/span><\/td>\n<td><span style=\"font-weight: 400\">170<\/span><\/td>\n<td><span style=\"font-weight: 400\">6.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">5 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">6.5 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL250<\/b><\/td>\n<td><span style=\"font-weight: 400\">10&#8243; (DN250)<\/span><\/td>\n<td><span style=\"font-weight: 400\">200<\/span><\/td>\n<td><span style=\"font-weight: 400\">6.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">6 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">9.2 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL300<\/b><\/td>\n<td><span style=\"font-weight: 400\">12&#8243; (DN300)<\/span><\/td>\n<td><span style=\"font-weight: 400\">230<\/span><\/td>\n<td><span style=\"font-weight: 400\">8.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">6 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">13.5 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL400<\/b><\/td>\n<td><span style=\"font-weight: 400\">16&#8243; (DN400)<\/span><\/td>\n<td><span style=\"font-weight: 400\">280<\/span><\/td>\n<td><span style=\"font-weight: 400\">8.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">6 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">22.0 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL500<\/b><\/td>\n<td><span style=\"font-weight: 400\">20&#8243; (DN500)<\/span><\/td>\n<td><span style=\"font-weight: 400\">340<\/span><\/td>\n<td><span style=\"font-weight: 400\">10.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">8 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">35.0 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-RCL600<\/b><\/td>\n<td><span style=\"font-weight: 400\">24&#8243; (DN600)<\/span><\/td>\n<td><span style=\"font-weight: 400\">400<\/span><\/td>\n<td><span style=\"font-weight: 400\">10.0 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">8 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">48.0 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Material &amp; Finish Specifications<\/b><\/h2>\n<h3><b>Steel Clamp Body<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Finish Type<\/b><\/td>\n<td><b>Coating Specification<\/b><\/td>\n<td><b>Recommended Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Electro-Galvanized (EG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">12\u201325 \u03bcm per ASTM B633<\/span><\/td>\n<td><span style=\"font-weight: 400\">Indoor mechanical shafts, dry riser rooms<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Hot-Dip Galvanized (HDG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u226555 \u03bcm per ASTM A153<\/span><\/td>\n<td><span style=\"font-weight: 400\">Outdoor risers, coastal environments, fire protection systems<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Pre-Galvanized (PG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standard mill coating<\/span><\/td>\n<td><span style=\"font-weight: 400\">General construction, standard building risers<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Plain (Uncoated)<\/b><\/td>\n<td><span style=\"font-weight: 400\">No coating<\/span><\/td>\n<td><span style=\"font-weight: 400\">Paint-ready or controlled indoor environments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><b>EPDM Lining Specification<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Material:<\/b><span style=\"font-weight: 400\"> EPDM (Ethylene Propylene Diene Monomer) high-density rubber<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Hardness:<\/b><span style=\"font-weight: 400\"> 65 \u00b1 5 Shore A<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Temperature Range:<\/b><span style=\"font-weight: 400\"> -20\u00b0C to +110\u00b0C<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Properties:<\/b><span style=\"font-weight: 400\"> Load-bearing under compression, water-resistant, thermal expansion-tolerant<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Function:<\/b><span style=\"font-weight: 400\"> Vibration damping, noise reduction (up to 18 dB), anti-galvanic protection, load cushioning<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Standards:<\/b><span style=\"font-weight: 400\"> ASTM D2000 compliant<\/span><\/li>\n<\/ul>\n<h2><b>Vertical Riser Support Application<\/b><\/h2>\n<p><span style=\"font-weight: 400\">The Riser Clamp with EPDM Lining is specifically designed for <\/span><b>vertical pipe systems that transfer dead weight through building structure<\/b><span style=\"font-weight: 400\">, providing:<\/span><\/p>\n<h3><b>Primary Functions<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Load Transfer:<\/b><span style=\"font-weight: 400\"> Carries full vertical dead weight (pipe + fluid + insulation) through structural floor or beam<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Alignment Control:<\/b><span style=\"font-weight: 400\"> Acts as rigid guide to maintain vertical alignment through floor penetrations<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Noise Isolation:<\/b><span style=\"font-weight: 400\"> EPDM lining reduces structure-borne vibration and thermal expansion noise up to 18 dB<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Pipe Protection:<\/b><span style=\"font-weight: 400\"> Prevents pipe surface damage at support points during thermal expansion\/contraction<\/span><\/li>\n<\/ul>\n<h3><b>Critical Design Note<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u26a0\ufe0f <\/span><b>NOT FOR THREADED ROD SUSPENSION<\/b><\/p>\n<p><span style=\"font-weight: 400\">This product is designed to REST on structural members, not to be suspended. The clamp transfers vertical load downward through compression. Do not attach threaded rods to this clamp for hanging applications\u2014use Pipe Hangers (NAC-SUP series) instead.<\/span><\/p>\n<h3><b>Key Performance Characteristics<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>High Load Capacity:<\/b><span style=\"font-weight: 400\"> Up to 5,800 kg (DN600\/24&#8243;) for heavy multi-story risers<\/span><\/li>\n<li style=\"font-weight: 400\"><b>18 dB Noise Reduction:<\/b><span style=\"font-weight: 400\"> Protects occupied spaces from pipe-transmitted structure noise<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Thermal Expansion Accommodation:<\/b><span style=\"font-weight: 400\"> EPDM compresses\/expands with pipe movement without chatter<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Installation Flexibility:<\/b><span style=\"font-weight: 400\"> Can be installed during initial pipe placement or added to existing risers<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Long-Term Reliability:<\/b><span style=\"font-weight: 400\"> EPDM maintains performance through repeated thermal cycles<\/span><\/li>\n<\/ul>\n<h3><b>Typical Installation Locations<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">High-rise building vertical risers (HVAC, plumbing, fire protection)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Mechanical shaft floor penetrations and support points<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Structural beam seats at equipment room levels<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Core wall riser supports in residential\/commercial towers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Plant room floor-level load transitions<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Multi-story drainage and vent stacks<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Fire protection standpipe and sprinkler risers<\/span><\/li>\n<\/ul>\n<h2><b>Application Selection Guide<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>System<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<td><b>Recommended Sizes<\/b><\/td>\n<td><b>Finish<\/b><\/td>\n<td><b>Critical Feature<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Fire Protection Risers<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standpipes, sprinkler mains<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN100\u2013DN300<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">High load capacity, code-compliant support<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>HVAC Chilled Water Risers<\/b><\/td>\n<td><span style=\"font-weight: 400\">Vertical distribution CHW\/HHW<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN50\u2013DN200<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Acoustic isolation in occupied buildings<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Domestic Water Risers<\/b><\/td>\n<td><span style=\"font-weight: 400\">Potable water vertical supply<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN40\u2013DN150<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Noise control for residential comfort<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Drainage &amp; Vent Stacks<\/b><\/td>\n<td><span style=\"font-weight: 400\">Waste, vent, roof drainage<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN65\u2013DN200<\/span><\/td>\n<td><span style=\"font-weight: 400\">Pre-Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Structure noise isolation during discharge<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Process Piping Risers<\/b><\/td>\n<td><span style=\"font-weight: 400\">Industrial vertical distribution<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN80\u2013DN300<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Heavy load capacity, thermal stability<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Building Service Mains<\/b><\/td>\n<td><span style=\"font-weight: 400\">Mixed-use high-rise systems<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN100\u2013DN600<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Maximum load capacity for large risers<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Installation Requirements<\/b><\/h2>\n<h3><b>Pre-Installation Checklist<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Structural Verification:<\/b><span style=\"font-weight: 400\"> Confirm floor\/beam can support calculated vertical load (pipe + fluid + insulation)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Load Calculation:<\/b><span style=\"font-weight: 400\"> Total riser weight from clamp to top = (pipe weight\/m \u00d7 height) + (fluid weight\/m \u00d7 height) + insulation<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Clamp Placement:<\/b><span style=\"font-weight: 400\"> Position clamp at structural support points per mechanical drawings (typically every floor or every other floor)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Support Surface:<\/b><span style=\"font-weight: 400\"> Ensure structural slab\/beam is level, clean, and free from deterioration<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Alignment Verification:<\/b><span style=\"font-weight: 400\"> Confirm pipe centerline alignment through floor sleeves before final clamping<\/span><\/li>\n<\/ul>\n<h3><b>Installation Procedure<\/b><\/h3>\n<ol>\n<li><b> Prepare structural support surface<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Clean and level structural slab or beam seat where clamp will rest<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> If using steel angle bracket, verify bracket is welded\/anchored per structural drawings<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Ensure support surface is continuous and will not deflect under load<\/span><\/p>\n<ol start=\"2\">\n<li><b> Position clamp on pipe below load point<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Open clamp by removing bolts<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Position clamp around pipe just BELOW any welded support lugs or load-bearing attachments<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Clamp should be positioned so load transfers through pipe wall to clamp, then to structure<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Inspect EPDM lining for proper seating\u2014ensure no gaps or displacement<\/span><\/p>\n<ol start=\"3\">\n<li><b> Close and bolt clamp assembly<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Align clamp halves around pipe<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Insert bolts (M10, M12, M16, or M20 depending on size)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Tighten bolts gradually in stages, alternating sides to ensure even compression<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Recommended torque:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M10: 40\u201345 Nm<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M12: 60\u201365 Nm<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M16: 120\u2013130 Nm<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">M20: 200\u2013220 Nm<\/span><\/li>\n<\/ul>\n<p><b>CRITICAL:<\/b><span style=\"font-weight: 400\"> Do not overtighten\u2014EPDM should compress but not extrude from clamp edges<\/span><\/p>\n<ol start=\"4\">\n<li><b> Seat clamp on structural support<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Lower pipe assembly so clamp rests fully on structural floor slab or beam<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify clamp is level and making full contact with support surface<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Ensure no gaps between clamp bottom and structural member<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> If using grout pad, allow grout to cure before loading<\/span><\/p>\n<ol start=\"5\">\n<li><b> Verify load path and alignment<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Check that vertical pipe alignment is maintained through floor sleeve<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Confirm no binding or misalignment at penetration points<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify clamp is not supporting lateral loads (use separate guides if needed)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Perform final walk-through inspection before system pressurization<\/span><\/p>\n<h3><b>Installation Spacing Guidelines<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Building Height<\/b><\/td>\n<td><b>Riser Clamp Spacing<\/b><\/td>\n<td><b>Additional Considerations<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Low-rise (1\u20135 floors)<\/span><\/td>\n<td><span style=\"font-weight: 400\">Every floor or every other floor<\/span><\/td>\n<td><span style=\"font-weight: 400\">Verify structural capacity of each support<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">Mid-rise (6\u201315 floors)<\/span><\/td>\n<td><span style=\"font-weight: 400\">Every floor for DN100+, every 2 floors for smaller<\/span><\/td>\n<td><span style=\"font-weight: 400\">Consider intermediate guides between load clamps<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400\">High-rise (16+ floors)<\/span><\/td>\n<td><span style=\"font-weight: 400\">Every floor for all sizes<\/span><\/td>\n<td><span style=\"font-weight: 400\">Seismic lateral restraints required per code<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Why Specify New Age Riser Clamps with EPDM Lining?<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Advantage<\/b><\/td>\n<td><b>Benefit to Your Project<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Integrated EPDM Lining<\/b><\/td>\n<td><span style=\"font-weight: 400\">Factory-installed rubber ensures consistent performance\u2014no field cutting or fitting required<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>18 dB Noise Reduction<\/b><\/td>\n<td><span style=\"font-weight: 400\">Meets acoustic comfort requirements in hospitals, hotels, residential towers without additional treatments<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>High Load Capacity<\/b><\/td>\n<td><span style=\"font-weight: 400\">Up to 5,800 kg per support point\u2014handles heavy multi-story risers without intermediate supports<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Thermal Expansion Isolation<\/b><\/td>\n<td><span style=\"font-weight: 400\">EPDM cushions thermal movement without metal-to-metal chatter or structure-transmitted noise<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Rigid Load-Bearing Design<\/b><\/td>\n<td><span style=\"font-weight: 400\">Two-piece bolted construction safely transfers vertical dead load to building structure<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>100% Egyptian Manufacturing<\/b><\/td>\n<td><span style=\"font-weight: 400\">3\u20137 day delivery (Cairo\/Giza), local technical support, competitive pricing vs. imports<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Certified Galvanization<\/b><\/td>\n<td><span style=\"font-weight: 400\">Long service life in mechanical shafts, outdoor risers, and coastal high-rise environments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Product Comparison: Riser Clamps vs. Other Supports<\/b><\/h2>\n<p><span style=\"font-weight: 400\">| Feature | <\/span><b>Riser Clamp w\/ Lining<\/b><span style=\"font-weight: 400\"> | <\/span><b>Pipe Hanger w\/ Lining<\/b><span style=\"font-weight: 400\"> | <\/span><b>Half Saddle<\/b><span style=\"font-weight: 400\"> | |&#8212;|&#8212;|&#8212;| | <\/span><b>Load Direction<\/b><span style=\"font-weight: 400\"> | Vertical (downward to floor) | Suspended (upward to ceiling) | Horizontal (into wall) | | <\/span><b>Mounting<\/b><span style=\"font-weight: 400\"> | Rests on structural floor\/beam | Hangs from threaded rod | Mounts to vertical wall | | <\/span><b>Vibration Isolation<\/b><span style=\"font-weight: 400\"> | \u2713 EPDM lining | \u2713 EPDM lining | \u2717 Metal contact | | <\/span><b>Noise Reduction<\/b><span style=\"font-weight: 400\"> | Up to 18 dB | Up to 18 dB | None | | <\/span><b>Load Capacity<\/b><span style=\"font-weight: 400\"> | 750\u20135,800 kg | 460\u2013950 kg | 35\u2013350 kg | | <\/span><b>Typical Use<\/b><span style=\"font-weight: 400\"> | Vertical risers (multi-story) | Horizontal ceiling runs | Wall-mounted horizontal\/vertical | | <\/span><b>Pipe Orientation<\/b><span style=\"font-weight: 400\"> | Vertical only | Horizontal only | Horizontal or vertical |<\/span><\/p>\n<h2><b>Riser System Design Considerations<\/b><\/h2>\n<h3><b>Load Calculation Example<\/b><\/h3>\n<p><b>Scenario:<\/b><span style=\"font-weight: 400\"> 10-story building with DN150 (6&#8243;) chilled water riser, 30m total height<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400\"><b>Pipe Weight:<\/b><span style=\"font-weight: 400\"> 40.3 kg\/m \u00d7 30m = 1,209 kg<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Fluid Weight (water):<\/b><span style=\"font-weight: 400\"> (\u03c0 \u00d7 0.1683\u00b2\/4) \u00d7 1000 kg\/m\u00b3 \u00d7 30m = 668 kg<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Insulation Weight:<\/b><span style=\"font-weight: 400\"> ~8 kg\/m \u00d7 30m = 240 kg<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Total Load:<\/b><span style=\"font-weight: 400\"> 1,209 + 668 + 240 = <\/span><b>2,117 kg<\/b><\/li>\n<\/ol>\n<p><b>Support Selection:<\/b><span style=\"font-weight: 400\"> NAC-RCL150 (max load 2,250 kg) \u2713 Adequate with safety margin<\/span><\/p>\n<p><b>Recommendation:<\/b><span style=\"font-weight: 400\"> Install riser clamps every 2-3 floors with intermediate pipe guides between clamps for alignment control.<\/span><\/p>\n<h3><b>Structural Coordination<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Floor Loading:<\/b><span style=\"font-weight: 400\"> Confirm structural drawings show adequate slab\/beam capacity at clamp locations<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Penetration Sleeves:<\/b><span style=\"font-weight: 400\"> Oversized sleeves (pipe OD + 100mm minimum) to allow thermal expansion<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Fire Stopping:<\/b><span style=\"font-weight: 400\"> Coordinate with fire protection contractor for proper sleeve fire-stop systems<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Seismic Bracing:<\/b><span style=\"font-weight: 400\"> In seismic zones, add lateral restraints per ASCE 7 or Egyptian Seismic Code<\/span><\/li>\n<\/ul>\n<h2><b>Standards &amp; Certifications<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>Egyptian Mechanical Code<\/b><span style=\"font-weight: 400\"> \u2013 Vertical riser support spacing, load calculations, structural coordination<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>NFPA 13<\/b><span style=\"font-weight: 400\"> \u2013 Fire protection riser support requirements (where applicable)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>MSS SP-58<\/b><span style=\"font-weight: 400\"> \u2013 Pipe support types and geometry equivalence (riser clamp category)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM B633<\/b><span style=\"font-weight: 400\"> \u2013 Electro-Galvanized coating specification (12\u201325 \u03bcm)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM A153<\/b><span style=\"font-weight: 400\"> \u2013 Hot-Dip Galvanized coating specification (\u226555 \u03bcm)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM D2000<\/b><span style=\"font-weight: 400\"> \u2013 EPDM rubber material specification<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>Egyptian Standard ES 138<\/b><span style=\"font-weight: 400\"> \u2013 Mild steel material classification (equivalent to ASTM A36)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ISO 9001:2015<\/b><span style=\"font-weight: 400\"> \u2013 Quality management system certification<\/span><\/li>\n<\/ul>\n<h2><b>Engineering Support<\/b><\/h2>\n<p><b>Technical Assistance:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Vertical riser load calculation verification (pipe + fluid + insulation weight)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Support spacing recommendations based on building height and pipe size<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Structural coordination for floor loading and beam seat design<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Acoustic performance calculations for noise-sensitive buildings<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Thermal expansion analysis for riser systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Seismic lateral restraint design (coordination with structural engineer)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">On-site installation guidance and contractor coordination<\/span><\/li>\n<\/ul>\n<p><b>Response Time:<\/b><span style=\"font-weight: 400\"> Technical queries answered within 24 hours<\/span><\/p>\n<p><b>After-Sales Support:<\/b><span style=\"font-weight: 400\"> Product issue resolution, installation troubleshooting, fast replacement for defects<\/span><\/p>\n<p><b>Custom Solutions:<\/b><span style=\"font-weight: 400\"> Special sizes (DN &gt; 600mm), heavy-duty brackets, or custom EPDM grades available for unique high-rise projects<\/span><\/p>\n<h2><b>Support Limitations &amp; Alternative Products<\/b><\/h2>\n<h3><b>When NOT to Use Riser Clamps<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u274c <\/span><b>Horizontal piping runs<\/b><span style=\"font-weight: 400\"> (use Pipe Hangers or Saddles instead)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Suspended ceiling applications<\/b><span style=\"font-weight: 400\"> (use Pipe Hangers with threaded rod)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Light-duty branch lines<\/b><span style=\"font-weight: 400\"> (oversized for small pipes\u2014use Saddles instead)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Applications without structural floor support<\/b><span style=\"font-weight: 400\"> (requires solid bearing surface)<\/span><\/p>\n<h3><b>Recommended Alternatives<\/b><\/h3>\n<p><span style=\"font-weight: 400\">For applications requiring different support characteristics:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>Horizontal ceiling runs:<\/b><span style=\"font-weight: 400\"> Use Pipe Hanger with EPDM Lining (NAC-SUP-1XX) suspended from threaded rod<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Wall-mounted vertical risers:<\/b><span style=\"font-weight: 400\"> Use Half Saddle (NAC-HS) for wall attachment<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Light branch lines:<\/b><span style=\"font-weight: 400\"> Use Light Saddle (NAC-LS) for smaller diameter pipes<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Adjustable height applications:<\/b><span style=\"font-weight: 400\"> Use clevis hangers with threaded rod adjustment<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Non-acoustic applications:<\/b><span style=\"font-weight: 400\"> Use Riser Clamp without lining for cost savings (if acoustic isolation not required)<\/span><\/li>\n<\/ul>\n<h2><b>Trusted on Major Projects<\/b><\/h2>\n<p><span style=\"font-weight: 400\">New Age Riser Clamps with EPDM Lining are specified across Egypt&#8217;s most demanding high-rise infrastructure:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Administrative Capital \u2013 Government tower HVAC and fire protection risers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Opera House Complex \u2013 Acoustic-sensitive vertical distribution systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Military Complex Projects \u2013 Secure facility mechanical risers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Giza Development \u2013 Residential high-rise plumbing and HVAC risers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Cairo Downtown High-Rises \u2013 Historic building retrofit vertical systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Upper Egypt Hospitals \u2013 Medical facility multi-story mechanical systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Red Sea Resort Towers \u2013 Coastal high-rise with corrosive environment protection<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Industrial High-Bay Facilities \u2013 Heavy process piping vertical distribution<\/span><\/li>\n<\/ul>\n<p><i><span style=\"font-weight: 400\">Trusted by leading contractors: Orascom Construction, Hassan Allam Holding, Arab Contractors<\/span><\/i><\/p>\n<p>&nbsp;<\/p>\n<h1><b>NEW AGE<\/b><\/h1>\n<p><i><span style=\"font-weight: 400\">\u062f\u0639\u0645 \u0645\u0627 \u064a\u0628\u0646\u064a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644<\/span><\/i><\/p>\n<p><span style=\"font-weight: 400\">100% Egyptian Manufacturing | ISO 9001:2015 Certified | Trusted by Egypt&#8217;s Top Contractors<\/span><\/p>","protected":false},"excerpt":{"rendered":"<h2><b>RISER CLAMP WITH EPDM LINING | NAC-RCL Series<\/b><\/h2>\n<h3><b>Load-Bearing Vertical Pipe Support &#8230; <\/p>","protected":false},"featured_media":2633,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[96],"product_tag":[],"class_list":{"0":"post-2631","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hvac-solutions","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product\/2631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/comments?post=2631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media\/2633"}],"wp:attachment":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media?parent=2631"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2631"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2631"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}