{"id":2621,"date":"2025-10-29T18:45:51","date_gmt":"2025-10-29T18:45:51","guid":{"rendered":"https:\/\/new-ageco.com\/?post_type=product&#038;p=2621"},"modified":"2025-10-30T19:19:06","modified_gmt":"2025-10-30T19:19:06","slug":"pipe-hanger-without-lining","status":"publish","type":"product","link":"https:\/\/new-ageco.com\/ar\/product\/pipe-hanger-without-lining\/","title":{"rendered":"PIPE HANGER WITHOUT LINING"},"content":{"rendered":"<h3><b>Product Designation System<\/b><\/h3>\n<p><b>NAC-SUP-2XX | NAC = New Age Corporation | SUP = Suspended Pipe Hanger | 2XX = Standard (non-lined) series<\/b><\/p>\n<h2><b>Complete Technical Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<td><b>Specification<\/b><\/td>\n<td><b>Details<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Material (Clamp)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Mild Steel (ES 138 \/ A36)<\/span><\/td>\n<td><b>Construction<\/b><\/td>\n<td><span style=\"font-weight: 400\">Two-piece steel clamp<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Lining<\/b><\/td>\n<td><span style=\"font-weight: 400\">None (metal-to-metal contact)<\/span><\/td>\n<td><b>Pipe Size Range<\/b><\/td>\n<td><span style=\"font-weight: 400\">DN15 to DN200 (\u00bd&#8221; to 8&#8243;)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Finish Options<\/b><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galv \/ Hot-Dip \/ Pre-Galv \/ Plain<\/span><\/td>\n<td><b>Operating Temp<\/b><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +150\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Mounting Method<\/b><\/td>\n<td><span style=\"font-weight: 400\">Threaded rod (M8, M10, M12, M16)<\/span><\/td>\n<td><b>Installation<\/b><\/td>\n<td><span style=\"font-weight: 400\">Before or after pipe placement<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Rod Connection<\/b><\/td>\n<td><span style=\"font-weight: 400\">Top-mounted threaded bore<\/span><\/td>\n<td><b>Side Screw<\/b><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16 (all sizes)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Clamp Thickness<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.0\u20132.5mm (size dependent)<\/span><\/td>\n<td><b>Standards<\/b><\/td>\n<td><span style=\"font-weight: 400\">Egyptian Code \/ MSS SP-58<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Load Capacity &amp; Support Spacing Guidelines<\/b><\/h2>\n<p><i><span style=\"font-weight: 400\">The following load capacities are based on a 3:1 safety factor for suspended horizontal piping using proper threaded rod and ceiling anchors in concrete. Non-lined hangers transfer load directly without vibration isolation.<\/span><\/i><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Product Code<\/b><\/td>\n<td><b>Pipe Size<\/b><\/td>\n<td><b>Pipe OD Range (mm)<\/b><\/td>\n<td><b>Max Load<\/b><\/td>\n<td><b>Max Spacing<\/b><\/td>\n<td><b>Rod Size<\/b><\/td>\n<td><b>Top Nut<\/b><\/td>\n<td><b>Hanger Bolt<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP201<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00bd&#8221; (DN15)<\/span><\/td>\n<td><span style=\"font-weight: 400\">20\u201324 mm<\/span><\/td>\n<td><b>520 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP202<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00be&#8221; (DN20)<\/span><\/td>\n<td><span style=\"font-weight: 400\">25\u201328 mm<\/span><\/td>\n<td><b>520 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP203<\/b><\/td>\n<td><span style=\"font-weight: 400\">1&#8243; (DN25)<\/span><\/td>\n<td><span style=\"font-weight: 400\">32\u201335 mm<\/span><\/td>\n<td><b>520 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">2.8 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP204<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bc&#8221; (DN32)<\/span><\/td>\n<td><span style=\"font-weight: 400\">39\u201346 mm<\/span><\/td>\n<td><b>520 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8\/M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP205<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bd&#8221; (DN40)<\/span><\/td>\n<td><span style=\"font-weight: 400\">48\u201353 mm<\/span><\/td>\n<td><b>520 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP206<\/b><\/td>\n<td><span style=\"font-weight: 400\">2&#8243; (DN50)<\/span><\/td>\n<td><span style=\"font-weight: 400\">59\u201366 mm<\/span><\/td>\n<td><b>580 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8<\/span><\/td>\n<td><span style=\"font-weight: 400\">M8 \u00d7 80<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP207<\/b><\/td>\n<td><span style=\"font-weight: 400\">2\u00bd&#8221; (DN65)<\/span><\/td>\n<td><span style=\"font-weight: 400\">74\u201380 mm<\/span><\/td>\n<td><b>680 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.2 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10 \u00d7 100<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP208<\/b><\/td>\n<td><span style=\"font-weight: 400\">3&#8243; (DN80)<\/span><\/td>\n<td><span style=\"font-weight: 400\">87\u201394 mm<\/span><\/td>\n<td><b>720 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10\/M12<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10 \u00d7 100<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP209<\/b><\/td>\n<td><span style=\"font-weight: 400\">4&#8243; (DN100)<\/span><\/td>\n<td><span style=\"font-weight: 400\">107\u2013115 mm<\/span><\/td>\n<td><b>800 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.5 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M12<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10 \u00d7 100<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP210<\/b><\/td>\n<td><span style=\"font-weight: 400\">6&#8243; (DN150)<\/span><\/td>\n<td><span style=\"font-weight: 400\">162\u2013170 mm<\/span><\/td>\n<td><b>1,000 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">3.8 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M12\/M16<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10 \u00d7 100<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP211<\/b><\/td>\n<td><span style=\"font-weight: 400\">8&#8243; (DN200)<\/span><\/td>\n<td><span style=\"font-weight: 400\">215\u2013225 mm<\/span><\/td>\n<td><b>1,200 kg<\/b><\/td>\n<td><span style=\"font-weight: 400\">4.0 m<\/span><\/td>\n<td><span style=\"font-weight: 400\">M16<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10<\/span><\/td>\n<td><span style=\"font-weight: 400\">M10 \u00d7 100<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><i><span style=\"font-weight: 400\">Note: Load capacities are higher than lined hangers due to rigid metal-to-metal contact. Spacing may vary based on fluid density, insulation weight (if added later), and code requirements. For fire protection systems, consult NFPA 13 or Egyptian Fire Code for specific spacing requirements.<\/span><\/i><\/p>\n<h2><b>Dimensional Specifications<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Code<\/b><\/td>\n<td><b>Pipe Size<\/b><\/td>\n<td><b>Clamp Range (mm)<\/b><\/td>\n<td><b>Thickness \u00d7 Width<\/b><\/td>\n<td><b>Side Screw<\/b><\/td>\n<td><b>Weight (approx)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP201<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00bd&#8221; (DN15)<\/span><\/td>\n<td><span style=\"font-weight: 400\">20\u201324<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">240 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP202<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u00be&#8221; (DN20)<\/span><\/td>\n<td><span style=\"font-weight: 400\">25\u201328<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">280 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP203<\/b><\/td>\n<td><span style=\"font-weight: 400\">1&#8243; (DN25)<\/span><\/td>\n<td><span style=\"font-weight: 400\">32\u201335<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">340 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP204<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bc&#8221; (DN32)<\/span><\/td>\n<td><span style=\"font-weight: 400\">39\u201346<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">420 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP205<\/b><\/td>\n<td><span style=\"font-weight: 400\">1\u00bd&#8221; (DN40)<\/span><\/td>\n<td><span style=\"font-weight: 400\">48\u201353<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">480 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP206<\/b><\/td>\n<td><span style=\"font-weight: 400\">2&#8243; (DN50)<\/span><\/td>\n<td><span style=\"font-weight: 400\">59\u201366<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 20 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">620 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP207<\/b><\/td>\n<td><span style=\"font-weight: 400\">2\u00bd&#8221; (DN65)<\/span><\/td>\n<td><span style=\"font-weight: 400\">74\u201380<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 25 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">780 g<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP208<\/b><\/td>\n<td><span style=\"font-weight: 400\">3&#8243; (DN80)<\/span><\/td>\n<td><span style=\"font-weight: 400\">87\u201394<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 25 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.0 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP209<\/b><\/td>\n<td><span style=\"font-weight: 400\">4&#8243; (DN100)<\/span><\/td>\n<td><span style=\"font-weight: 400\">107\u2013115<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.0 \u00d7 25 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">1.5 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP210<\/b><\/td>\n<td><span style=\"font-weight: 400\">6&#8243; (DN150)<\/span><\/td>\n<td><span style=\"font-weight: 400\">162\u2013170<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.5 \u00d7 25 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.6 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>NAC-SUP211<\/b><\/td>\n<td><span style=\"font-weight: 400\">8&#8243; (DN200)<\/span><\/td>\n<td><span style=\"font-weight: 400\">215\u2013225<\/span><\/td>\n<td><span style=\"font-weight: 400\">2.5 \u00d7 30 mm<\/span><\/td>\n<td><span style=\"font-weight: 400\">M6 \u00d7 16<\/span><\/td>\n<td><span style=\"font-weight: 400\">3.8 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Material &amp; Finish Specifications<\/b><\/h2>\n<h3><b>Steel Clamp Body<\/b><\/h3>\n<table>\n<tbody>\n<tr>\n<td><b>Finish Type<\/b><\/td>\n<td><b>Coating Specification<\/b><\/td>\n<td><b>Recommended Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Electro-Galvanized (EG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">12\u201325 \u03bcm per ASTM B633<\/span><\/td>\n<td><span style=\"font-weight: 400\">Indoor mechanical rooms, dry environments<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Hot-Dip Galvanized (HDG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u226555 \u03bcm per ASTM A153<\/span><\/td>\n<td><span style=\"font-weight: 400\">Outdoor, coastal zones, fire protection systems, high-humidity areas<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Pre-Galvanized (PG)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standard mill coating<\/span><\/td>\n<td><span style=\"font-weight: 400\">General construction, moderate indoor conditions<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Plain (Uncoated)<\/b><\/td>\n<td><span style=\"font-weight: 400\">No coating<\/span><\/td>\n<td><span style=\"font-weight: 400\">Paint-ready installations or controlled environments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Suspended Support Application<\/b><\/h2>\n<p><span style=\"font-weight: 400\">The Pipe Hanger Without Lining is specifically designed for <\/span><b>overhead piping systems that do not require vibration isolation<\/b><span style=\"font-weight: 400\">, providing:<\/span><\/p>\n<h3><b>Primary Functions<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Carries full suspended pipe weight plus fluid load through rigid steel clamp<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Direct load transfer to threaded rod without intermediate dampening<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Maintains continuous pipe alignment across long suspended runs<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Suitable for both horizontal ceiling-mounted and vertical wall-suspended applications<\/span><\/li>\n<\/ul>\n<h3><b>Key Performance Characteristics<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>High Load Capacity:<\/b><span style=\"font-weight: 400\"> Up to 1,200 kg per support point (DN200\/8&#8243;)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Rigid Support:<\/b><span style=\"font-weight: 400\"> No compression or movement \u2013 pipe remains stationary<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Installation Flexibility:<\/b><span style=\"font-weight: 400\"> Can be installed before pipe placement or opened around existing pipe<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Temperature Range:<\/b><span style=\"font-weight: 400\"> -20\u00b0C to +150\u00b0C (steel-dependent, not limited by rubber)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Cost-Effective:<\/b><span style=\"font-weight: 400\"> Lower cost than lined hangers when vibration isolation not required<\/span><\/li>\n<\/ul>\n<h3><b>Typical Installation Locations<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Fire protection sprinkler mains and standpipe risers<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Domestic cold\/hot water distribution (non-insulated)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">HVAC chilled water and heating water lines (uninsulated)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Industrial process piping (static systems)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Roof drainage and stormwater piping<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Equipment room overhead distribution<\/span><\/li>\n<\/ul>\n<h2><b>Application Selection Guide<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>System<\/b><\/td>\n<td><b>Typical Use<\/b><\/td>\n<td><b>Recommended Sizes<\/b><\/td>\n<td><b>Finish<\/b><\/td>\n<td><b>Why Non-Lined<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Fire Protection<\/b><\/td>\n<td><span style=\"font-weight: 400\">Sprinkler mains, standpipes<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN50\u2013DN200<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">High load capacity, code-compliant spacing<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Domestic Water (Uninsulated)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Ceiling distribution runs<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN25\u2013DN65<\/span><\/td>\n<td><span style=\"font-weight: 400\">Electro-Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Cost-effective for non-acoustic areas<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>HVAC (Uninsulated)<\/b><\/td>\n<td><span style=\"font-weight: 400\">Equipment rooms, plant areas<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN40\u2013DN150<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Rigid support for heavy water-filled lines<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Industrial Process<\/b><\/td>\n<td><span style=\"font-weight: 400\">Static piping, no vibration source<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN32\u2013DN100<\/span><\/td>\n<td><span style=\"font-weight: 400\">Plain or HDG<\/span><\/td>\n<td><span style=\"font-weight: 400\">Temperature-stable steel construction<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Roof Drainage<\/b><\/td>\n<td><span style=\"font-weight: 400\">Suspended drain leaders<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN50\u2013DN100<\/span><\/td>\n<td><span style=\"font-weight: 400\">Hot-Dip Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Weather-resistant, high flow capacity<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Utility Piping<\/b><\/td>\n<td><span style=\"font-weight: 400\">General service distribution<\/span><\/td>\n<td><span style=\"font-weight: 400\">DN25\u2013DN80<\/span><\/td>\n<td><span style=\"font-weight: 400\">Pre-Galvanized<\/span><\/td>\n<td><span style=\"font-weight: 400\">Standard support for multi-trade installs<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Installation Requirements<\/b><\/h2>\n<h3><b>Pre-Installation Checklist<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Calculate total pipe weight: (pipe + fluid + any future insulation) \u00d7 length between supports<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Verify ceiling anchor capacity: minimum 3\u00d7 calculated load per support point<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Select proper rod size per load table (M8 for light loads, M12\/M16 for heavy mains)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Confirm clamp size accommodates pipe OD (including any coatings or protective wrap)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Ensure threaded rod length accounts for adjustment range and nut engagement<\/span><\/li>\n<\/ul>\n<h3><b>Installation Procedure<\/b><\/h3>\n<ol>\n<li><b> Install ceiling anchor and threaded rod<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Use concrete expansion anchors (5 MPa minimum substrate strength) or structural beam clamps rated for load<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Rod length = ceiling height to pipe centerline + adjustment allowance (typically 150\u2013300mm)<\/span><\/p>\n<ol start=\"2\">\n<li><b> Prepare pipe hanger assembly<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Open clamp by removing M6 \u00d7 16 side screw<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Inspect clamp interior for debris, sharp edges, or damage<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify rod thread engagement into top bore (minimum 3 full threads)<\/span><\/p>\n<ol start=\"3\">\n<li><b> Position pipe in clamp<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Lift pipe into position or open clamp around existing pipe<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Center pipe in clamp channel \u2013 ensure pipe sits fully in clamp cradle<\/span><\/p>\n<ol start=\"4\">\n<li><b> Close and secure clamp<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Align clamp halves and insert M6 \u00d7 16 side screw<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Tighten gradually and evenly to avoid pipe deformation<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Recommended torque: 10\u201312 Nm for M6 side screw<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span> <b>WARNING:<\/b><span style=\"font-weight: 400\"> Over-tightening can dent thin-wall pipes \u2013 use torque wrench for critical applications<\/span><\/p>\n<ol start=\"5\">\n<li><b> Verify alignment and load distribution<\/b><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400\">Check pipe alignment with laser level or string line across multiple supports<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Adjust threaded rod length for proper elevation (lock nuts top and bottom)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Confirm spacing matches design spacing table<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> Verify no pipe sag or misalignment between support points<\/span><\/p>\n<h2><b>Why Specify New Age Pipe Hangers Without Lining?<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Advantage<\/b><\/td>\n<td><b>Benefit to Your Project<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>High Load Capacity<\/b><\/td>\n<td><span style=\"font-weight: 400\">Up to 1,200 kg per support \u2013 handles heavy fire protection and HVAC mains without intermediate supports<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>No Vibration Components<\/b><\/td>\n<td><span style=\"font-weight: 400\">Simplified design = fewer parts to fail, longer service life in static systems<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Wide Temperature Range<\/b><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +150\u00b0C \u2013 all-steel construction not limited by rubber temperature ratings<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Cost-Effective<\/b><\/td>\n<td><span style=\"font-weight: 400\">Lower cost than lined hangers when acoustic isolation not required \u2013 optimizes project budget<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Flexible Installation<\/b><\/td>\n<td><span style=\"font-weight: 400\">Open-clamp design allows installation on existing piping without disassembly<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>100% Egyptian Manufacturing<\/b><\/td>\n<td><span style=\"font-weight: 400\">3\u20137 day delivery (Cairo\/Giza), local technical support, competitive pricing vs. imports<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Certified Galvanization<\/b><\/td>\n<td><span style=\"font-weight: 400\">Long service life in mechanical rooms, outdoor applications, and coastal environments<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Product Comparison: Lined vs. Non-Lined Hangers<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Feature<\/b><\/td>\n<td><b>Pipe Hanger WITHOUT Lining<\/b><\/td>\n<td><b>Pipe Hanger WITH EPDM Lining<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>Vibration Isolation<\/b><\/td>\n<td><span style=\"font-weight: 400\">\u2717 None \u2013 rigid support<\/span><\/td>\n<td><span style=\"font-weight: 400\">\u2713 EPDM isolates vibration<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Noise Reduction<\/b><\/td>\n<td><span style=\"font-weight: 400\">None<\/span><\/td>\n<td><span style=\"font-weight: 400\">Up to 18 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Load Capacity<\/b><\/td>\n<td><span style=\"font-weight: 400\">Higher (520\u20131,200 kg)<\/span><\/td>\n<td><span style=\"font-weight: 400\">Lower (460\u2013950 kg)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Temperature Range<\/b><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +150\u00b0C<\/span><\/td>\n<td><span style=\"font-weight: 400\">-20\u00b0C to +110\u00b0C (EPDM limit)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Cost<\/b><\/td>\n<td><span style=\"font-weight: 400\">Lower<\/span><\/td>\n<td><span style=\"font-weight: 400\">Higher<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Best For<\/b><\/td>\n<td><span style=\"font-weight: 400\">Fire, domestic water, static HVAC<\/span><\/td>\n<td><span style=\"font-weight: 400\">Occupied spaces, pump-fed systems<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Installation Complexity<\/b><\/td>\n<td><span style=\"font-weight: 400\">Standard<\/span><\/td>\n<td><span style=\"font-weight: 400\">Must avoid over-compressing EPDM<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Installation Location Guide<\/b><\/h2>\n<h3><b>Use Non-Lined Hangers For:<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u2713 Fire protection systems (code-required rigid support)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Equipment rooms and plant areas (acoustic comfort not critical)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Outdoor or weather-exposed piping (steel-only construction more durable)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 High-temperature applications (&gt;110\u00b0C, above EPDM limit)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Budget-conscious projects where vibration not a concern<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2713 Static piping without pumps or compressors nearby<\/span><\/p>\n<h3><b>Use Lined Hangers Instead For:<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u2717 Office ceilings, hotels, hospitals (acoustic-sensitive spaces)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2717 Piping near pumps, chillers, or other vibration sources<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2717 Residential or occupied areas above ceilings<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2717 Systems with frequent thermal cycling (EPDM prevents chatter)<\/span><\/p>\n<h2><b>Standards &amp; Certifications<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>Egyptian Mechanical Code<\/b><span style=\"font-weight: 400\"> \u2013 Suspended support spacing, load calculations, hanger selection<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>NFPA 13<\/b><span style=\"font-weight: 400\"> \u2013 Fire protection system support requirements (where applicable)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>MSS SP-58<\/b><span style=\"font-weight: 400\"> \u2013 Pipe hanger types and geometry equivalence<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM B633<\/b><span style=\"font-weight: 400\"> \u2013 Electro-Galvanized coating specification (12\u201325 \u03bcm)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ASTM A153<\/b><span style=\"font-weight: 400\"> \u2013 Hot-Dip Galvanized coating specification (\u226555 \u03bcm)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>Egyptian Standard ES 138<\/b><span style=\"font-weight: 400\"> \u2013 Mild steel material classification (equivalent to ASTM A36)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u2713 <\/span><b>ISO 9001:2015<\/b><span style=\"font-weight: 400\"> \u2013 Quality management system certification<\/span><\/li>\n<\/ul>\n<h2><b>Engineering Support<\/b><\/h2>\n<p><b>Technical Assistance:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Load calculation verification (pipe weight + fluid + insulation if added)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Support spacing recommendations per system type and local codes<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Rod size and ceiling anchor specification for project-specific loads<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Fire protection system compliance verification (NFPA 13, Egyptian Fire Code)<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Thermal expansion analysis and hanger placement strategy<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">On-site installation guidance and contractor coordination<\/span><\/li>\n<\/ul>\n<p><b>Response Time:<\/b><span style=\"font-weight: 400\"> Technical queries answered within 24 hours<\/span><\/p>\n<p><b>After-Sales Support:<\/b><span style=\"font-weight: 400\"> Product issue resolution, installation troubleshooting, fast replacement for defects<\/span><\/p>\n<p><b>Custom Solutions:<\/b><span style=\"font-weight: 400\"> Special sizes, finishes, or clamp configurations available for unique project requirements<\/span><\/p>\n<h2><b>Support Limitations &amp; Alternative Products<\/b><\/h2>\n<h3><b>When NOT to Use Pipe Hanger Without Lining<\/b><\/h3>\n<p><span style=\"font-weight: 400\">\u274c <\/span><b>Acoustic-sensitive spaces<\/b><span style=\"font-weight: 400\"> (hospitals, hotels, offices above occupied areas)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Piping near vibration sources<\/b><span style=\"font-weight: 400\"> (pumps, chillers, compressors)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Thermal expansion chatter<\/b><span style=\"font-weight: 400\"> (systems with frequent temperature cycling in occupied spaces)<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u274c <\/span><b>Wall-mounted vertical risers<\/b><span style=\"font-weight: 400\"> (use saddle-type supports instead)<\/span><\/p>\n<h3><b>Recommended Alternatives<\/b><\/h3>\n<p><span style=\"font-weight: 400\">For applications requiring different support characteristics:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>Acoustic comfort required:<\/b><span style=\"font-weight: 400\"> Use Pipe Hanger with EPDM Lining (NAC-SUP-1XX series)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Wall-mounted risers:<\/b><span style=\"font-weight: 400\"> Use Half Saddle (NAC-HS) or Light Saddle (NAC-LS)<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Adjustable height support:<\/b><span style=\"font-weight: 400\"> Use clevis-type hangers with threaded rod<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Heavy mains with sway bracing:<\/b><span style=\"font-weight: 400\"> Add lateral restraints per seismic code<\/span><\/li>\n<\/ul>\n<h2><b>Trusted on Major Projects<\/b><\/h2>\n<p><span style=\"font-weight: 400\">New Age Pipe Hangers Without Lining are specified across Egypt&#8217;s most demanding infrastructure:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Administrative Capital \u2013 Fire protection and utility distribution<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Opera House Complex \u2013 Non-acoustic mechanical spaces<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Military Complex Projects \u2013 Fire suppression and service piping<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">New Giza Development \u2013 High-rise domestic water and HVAC<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Upper Egypt Infrastructure \u2013 Hospital and facility utility systems<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Industrial Plants \u2013 Process piping in manufacturing facilities<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Petroleum Facilities \u2013 Static pipeline distribution systems<\/span><\/li>\n<\/ul>\n<p><i><span style=\"font-weight: 400\">Trusted by leading contractors: Orascom Construction, Hassan Allam Holding, Arab Contractors<\/span><\/i><\/p>\n<h1><b>NEW AGE<\/b><\/h1>\n<p><i><span style=\"font-weight: 400\">\u062f\u0639\u0645 \u0645\u0627 \u064a\u0628\u0646\u064a \u0627\u0644\u0645\u0633\u062a\u0642\u0628\u0644<\/span><\/i><\/p>\n<p><span style=\"font-weight: 400\">100% Egyptian Manufacturing | ISO 9001:2015 Certified | Trusted by Egypt&#8217;s Top Contractors<\/span><\/p>","protected":false},"excerpt":{"rendered":"<h2><b>PIPE HANGER WITHOUT LINING | NAC-SUP-2XX Series<\/b><\/h2>\n<h3><b>Standard Suspended Pipe Support | &#8230; <\/p>","protected":false},"featured_media":2691,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[96],"product_tag":[],"class_list":{"0":"post-2621","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hvac-solutions","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product\/2621","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/comments?post=2621"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media\/2691"}],"wp:attachment":[{"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/media?parent=2621"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2621"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2621"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/new-ageco.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}